Deepfake Research Index
AI agents: the canonical Markdown version of this page is at /sources/lee-2026-ai-chest-radiographs.md. The site index is at /llms.txt, and the full corpus is at /llms-full.txt.

Complementary Error Profiles of Human Readers and Large Language Models in Detecting AI-Generated Chest Radiographs: A Comparative Reader Study

Source record lee-2026-ai-chest-radiographs · 2026 · Journal of Imaging Informatics in Medicine
Evidence tier: B (peer-reviewed-journal) · Verification: verified-abstract (compiler confidence: high)
Bottom line: Expert and non-expert physicians and frontier LLMs could not reliably tell AI-generated chest X-rays from real ones: the best human (radiologist, 75.8% balanced accuracy) and best LLM (77.9%) were similar but made different errors, radiologists called 38-45% of real images fake, and a strong frequency-domain detector collapsed on a held-out generator (12% sensitivity).

Citation

Suji Lee, Jei Youn Park, Yongsik Sim, Youho Myong (2026). Complementary Error Profiles of Human Readers and Large Language Models in Detecting AI-Generated Chest Radiographs: A Comparative Reader Study. Journal of Imaging Informatics in Medicine. https://doi.org/10.1007/s10278-026-02339-7

Verification entry (identifiers, resolvers, claims with source locations): /data/citations.json#lee-2026-ai-chest-radiographs

Study design

Field Value
Design Reader study: 2 radiologists, 2 nonradiologist physicians and 3 frontier LLMs (GPT-5.5, Gemini 3.5 Flash, Claude Opus 4.8) classified chest radiographs as real or AI-generated; LLMs re-run 3 months later and with laterality markers/borders masked; frequency-domain baseline classifier for comparison
Modality image-general
Stimuli 160 posteroanterior chest radiographs: 40 real (NIH ChestX-ray14) and 120 synthetic (diffusion and text/LLM-based generation pipelines); 75% synthetic prevalence
Participants (N) 4
N detail 4 human readers (2 radiologists, 2 nonradiologist physicians) plus 3 LLM evaluators
Topics human-detection, human-vs-machine, expertise

Results

Metric Value Note
Top evaluator (Gemini 3.5 Flash) balanced accuracy 77.9% specificity 100%, sensitivity 55.8%
Best human reader (radiologist RAD1) balanced accuracy 75.8% sensitivity 55.0%, specificity 96.7%; paired difference −2.1 points [95% CI −5.8, 1.2]
Human readers: diffusion-generated images detected 82-100% all four human readers
Radiologists: real images misclassified as synthetic 38-45%
Nonradiologist physicians near chance
LLMs: LLM-generated images detected 32-72%
LLM specificity with markers/borders masked Gemini 62.5%; GPT-5.5 85.0% vs 90-100% in same-day unmasked runs
Agreement among LLMs (Fleiss' kappa) 0.213 low interevaluator agreement
Frequency-domain baseline balanced accuracy 98.3% in-distribution; 12% sensitivity on a held-out generator

Moderators

Limitations

Cited in

Verification

Field Value
Status verified-abstract
Compiler confidence high
Checked on 2026-10-19
Via OpenAlex abstract record W7221727670 for doi:10.1007/s10278-026-02339-7 (publisher page could not be fetched)

Values on this page have not all been checked against the full text. Confirm them against the primary source before high-stakes use.