type: source
id: lee-2026-ai-chest-radiographs
title: 'Complementary Error Profiles of Human Readers and Large Language Models in Detecting AI-Generated Chest Radiographs: A Comparative Reader Study'
authors:
- Suji Lee
- Jei Youn Park
- Yongsik Sim
- Youho Myong
year: 2026
venue: Journal of Imaging Informatics in Medicine
volume: null
pages: null
doi: 10.1007/s10278-026-02339-7
pmid: '42867583'
pmcid: null
arxiv_id: null
openalex_id: W7221727670
oa_url: https://link.springer.com/content/pdf/10.1007/s10278-026-02339-7.pdf
peer_review: peer-reviewed-journal
evidence_tier: B
design: 'Reader study: 2 radiologists, 2 nonradiologist physicians and 3 frontier LLMs (GPT-5.5, Gemini 3.5 Flash, Claude Opus 4.8) classified chest radiographs as real or AI-generated; LLMs re-run 3 months later and with laterality markers/borders masked; frequency-domain baseline classifier for comparison'
modality:
- image-general
stimuli: '160 posteroanterior chest radiographs: 40 real (NIH ChestX-ray14) and 120 synthetic (diffusion and text/LLM-based generation pipelines); 75% synthetic prevalence'
n_participants: 4
n_note: 4 human readers (2 radiologists, 2 nonradiologist physicians) plus 3 LLM evaluators
topics:
- human-detection
- human-vs-machine
- expertise
summary: 'Expert and non-expert physicians and frontier LLMs could not reliably tell AI-generated chest X-rays from real ones: the best human (radiologist, 75.8% balanced accuracy) and best LLM (77.9%) were similar but made different errors, radiologists called 38-45% of real images fake, and a strong frequency-domain detector collapsed on a held-out generator (12% sensitivity).'
results:
- metric: Top evaluator (Gemini 3.5 Flash) balanced accuracy
  value: 77.9%
  note: specificity 100%, sensitivity 55.8%
  source_location: abstract
- metric: Best human reader (radiologist RAD1) balanced accuracy
  value: 75.8%
  note: sensitivity 55.0%, specificity 96.7%; paired difference −2.1 points [95% CI −5.8, 1.2]
  source_location: abstract
- metric: 'Human readers: diffusion-generated images detected'
  value: 82-100%
  note: all four human readers
  source_location: abstract
- metric: 'Radiologists: real images misclassified as synthetic'
  value: 38-45%
  note: ''
  source_location: abstract
- metric: Nonradiologist physicians
  value: near chance
  note: ''
  source_location: abstract
- metric: 'LLMs: LLM-generated images detected'
  value: 32-72%
  note: ''
  source_location: abstract
- metric: LLM specificity with markers/borders masked
  value: Gemini 62.5%; GPT-5.5 85.0%
  note: vs 90-100% in same-day unmasked runs
  source_location: abstract
- metric: Agreement among LLMs (Fleiss' kappa)
  value: '0.213'
  note: low interevaluator agreement
  source_location: abstract
- metric: Frequency-domain baseline
  value: balanced accuracy 98.3% in-distribution; 12% sensitivity on a held-out generator
  note: ''
  source_location: abstract
moderators:
- 'Generator type: diffusion images were caught by humans far more often than LLM/text-pipeline images were caught by LLMs.'
- 'Expertise: radiologists outperformed nonradiologists but at the cost of many false alarms on real images.'
limitations:
- Four human readers
- Medical images only
- Values from abstract; full text not read
- Fixed 75% synthetic prevalence
verification:
  status: verified-abstract
  confidence: high
  checked: 2026-10-19
  via: OpenAlex abstract record W7221727670 for doi:10.1007/s10278-026-02339-7 (publisher page could not be fetched)
url: null
cited_in:
- MR-0001
updated: '2026-10-19'
---

# Complementary Error Profiles of Human Readers and Large Language Models in Detecting AI-Generated Chest Radiographs: A Comparative Reader Study

> **Source record** `lee-2026-ai-chest-radiographs` · 2026 · Journal of Imaging Informatics in Medicine  
> **Evidence tier:** B (peer-reviewed-journal) · **Verification:** verified-abstract (compiler confidence: high)  
> **Bottom line:** Expert and non-expert physicians and frontier LLMs could not reliably tell AI-generated chest X-rays from real ones: the best human (radiologist, 75.8% balanced accuracy) and best LLM (77.9%) were similar but made different errors, radiologists called 38-45% of real images fake, and a strong frequency-domain detector collapsed on a held-out generator (12% sensitivity).

## Citation {#citation}

Suji Lee, Jei Youn Park, Yongsik Sim, Youho Myong (2026). Complementary Error Profiles of Human Readers and Large Language Models in Detecting AI-Generated Chest Radiographs: A Comparative Reader Study. *Journal of Imaging Informatics in Medicine*. https://doi.org/10.1007/s10278-026-02339-7

Verification entry (identifiers, resolvers, claims with source locations): [/data/citations.json#lee-2026-ai-chest-radiographs](/data/citations.json#lee-2026-ai-chest-radiographs)

## Study design {#design}

| Field | Value |
|---|---|
| Design | Reader study: 2 radiologists, 2 nonradiologist physicians and 3 frontier LLMs (GPT-5.5, Gemini 3.5 Flash, Claude Opus 4.8) classified chest radiographs as real or AI-generated; LLMs re-run 3 months later and with laterality markers/borders masked; frequency-domain baseline classifier for comparison |
| Modality | image-general |
| Stimuli | 160 posteroanterior chest radiographs: 40 real (NIH ChestX-ray14) and 120 synthetic (diffusion and text/LLM-based generation pipelines); 75% synthetic prevalence |
| Participants (N) | 4 |
| N detail | 4 human readers (2 radiologists, 2 nonradiologist physicians) plus 3 LLM evaluators |
| Topics | human-detection, human-vs-machine, expertise |

## Results {#results}

| Metric | Value | Note |
|---|---|---|
| Top evaluator (Gemini 3.5 Flash) balanced accuracy | 77.9% | specificity 100%, sensitivity 55.8% |
| Best human reader (radiologist RAD1) balanced accuracy | 75.8% | sensitivity 55.0%, specificity 96.7%; paired difference −2.1 points [95% CI −5.8, 1.2] |
| Human readers: diffusion-generated images detected | 82-100% | all four human readers |
| Radiologists: real images misclassified as synthetic | 38-45% |  |
| Nonradiologist physicians | near chance |  |
| LLMs: LLM-generated images detected | 32-72% |  |
| LLM specificity with markers/borders masked | Gemini 62.5%; GPT-5.5 85.0% | vs 90-100% in same-day unmasked runs |
| Agreement among LLMs (Fleiss' kappa) | 0.213 | low interevaluator agreement |
| Frequency-domain baseline | balanced accuracy 98.3% in-distribution; 12% sensitivity on a held-out generator |  |

## Moderators {#moderators}

- Generator type: diffusion images were caught by humans far more often than LLM/text-pipeline images were caught by LLMs.
- Expertise: radiologists outperformed nonradiologists but at the cost of many false alarms on real images.

## Limitations {#limitations}

- Four human readers
- Medical images only
- Values from abstract; full text not read
- Fixed 75% synthetic prevalence

## Cited in {#cited-in}

- [MR-0001](/metareports/human-detection-accuracy.md): Human Detection of Deepfakes: Accuracy, Bias, Confidence, and Training

## Verification {#verification}

| Field | Value |
|---|---|
| Status | `verified-abstract` |
| Compiler confidence | high |
| Checked on | 2026-10-19 |
| Via | OpenAlex abstract record W7221727670 for doi:10.1007/s10278-026-02339-7 (publisher page could not be fetched) |

Values on this page have not all been checked against the full text. Confirm them against the primary source before high-stakes use.